19291 - DIGITAL SURFACE RESISTANCE METER


Internet List Pricing Fax / Email List Price
Qty: 1 $2165.75
Qty: 1 $2382.33

* This is not a formal quote. Prices may change without notice.


Features

  • NEW large OLED display
    Displays resistance mantissa and exponent, temperature, relative humidity and test voltage
  • NEW internal memory
    Stores and recalls up to 100 measurements. Captures resistance, temperature, humidity and test voltage
  • NEW measurement stability modes
    Sets the 15-second electrification period for test requirements*
  • NEW electrode spacers
    Spaces the 2.27 kg electrodes to 25 and 91 cm for resistance point-to-point (Rtt) measurement requirements of IEC 61340-2-3 and IEC 61340-4-1
  • NEW measurement location labels (pack of 25)
    Labels and tracks areas and materials measured for surface resistance
  • Digital compliance verification surface resistance meter kit
    Measures resistance point-to-point (Rtt) and resistance-to-ground (Rtg) of worksurfaces, flooring systems, garments, packaging, and other materials in accordance with IEC 61340-2-3 and IEC 61340-5-1
  • Resistance range: <1.0 x 103 to >1.0 x 1012 Ohms
    Determines if a surface is conductive, dissipative or insulative for ESD control applications in electronics manufacturing or handling environments
  • Under load test voltages (10 V or 100 V ±5 %)
    Meets ANSI/ESD S20.20 resistance testing requirements for product qualification and compliance verification
  • 222002 Concentric Ring Probe Accessory 
    Measures surface resistance per IEC 61340-2-3, the test method listed in Packaging Table 3 in EN 61340-5-1
  • NEW 19295 handheld Electrode Accessory
    Meets resistance measurement requirements of IEC 61340-2-3, IEC 61340-4-1, ANSI/ESD STM2.1 and IEC 61340-4-5
  • NIST Calibrated – Original Calibration Certificate can be Downloaded Here
    Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology. For more information on the calibration of Desco Europe products, see Calibration.
  • Made in the United States of America

 

*Measurement stability modes:
Auto stabilisation enables a 15-second electrification period when the measured resistance is 1 x 1010 ohms or greater to maintain test accuracy.

Fixed stabilisation complies with ANSI/ESD S4.1 and enables a 15-second electrification period when the measured resistance is 1 x 106 ohms or greater.


Technical Information

  • TB-3076.E - Digital Surface Resistance Meter Kit - Installation, Operation and Maintenance