We Refuse to Put Your Products at Risk |
|
ESD S1.1 sample minimum life | 8,000 |
ESD S1.1 all samples average life | 16,000 |
TEST COMPLETED 2/20/06 | |
Jewel Dual Wire Sample 1 | 11,762,000 |
Jewel Dual Wire Sample 2 | 11,762,000 |
TEST COMPLETED 6/25/03 | |
Jewel Rapid Retraction Sample 1 | 52,576,321 |
Jewel Rapid Retraction Sample 2 | 52,976,392 |
Jewel Rapid Retraction Sample 3 | 51,992,914 |
Jewel Rapid Retraction Sample 4 | 53,012,060 |
TEST CONCLUDED 12/01/00 | |
Black Relaxed Retraction Sample 1 | 1,176,172 |
Black Relaxed Retraction Sample 2 | 932,147 |
Black Relaxed Retraction Sample 3 | 1,217,333 |
Black Relaxed Retraction Sample 4 | 976,451 |
Reliable Circuit Connections Bending Life Test per ESD S1.1 |
|
Per ESD Handbook TR20.20 paragraph 5.3.2.2.2 Wrist Strap Ground Cord "At first glance, the ground cord appears to be a relatively simple assembly. However, the design requirements are considerable, given the wide range of user applications and the durability requirements of constant tugging, flexing, and dragging over the edge of workstation tops and equipment chassis." |
|
Per ESD S1.1, Coil Cords should be tested on a machine like the one shown here. |